chromatographic columns usp

Chromatographic Columns USP
The designation for a new column will receive a number ONLY when the text referring to this column becomes official,whether in a Supplement,in the next USP–NF,or in a Revision Bulletin or Interim Revision Announcement.During the proposal period in Pharmacopeial Forum,the new chromatographic column will be identified in the database by “L##,” “G##,” or “S##” followed by the monograph title and the columnChromatographic Database Provides The Following Column DataHow Chromatographic Database Assists The UserNotice and DisclaimerThe identification of the chromatographic column by brand name is furnished for information purposes to indicate the market availability of the column that corresponds to the USP description.A listing does not imply approval,endorsement,or certification of a particular brand or product,nor does the omission of a particular brand or product indicate that the article was judged to be unsatisfactory or inadequate.The list of brand names is not comprehensive.It was compiled from information in supplier or manufacturer catSee more on uspLogin - USP Access PointWelcome to Access Point! Use your USP Access Point login credentials to register for events and courses,access your subscriptions to USP's free resources,applications,and more.sp.infoImages of Chromatographic Columns USP
Read MoreUSP 35 Reagents / Chromatographic Columns1085
1086Chromatographic Columns / Reagents USP 35 L3—Porous silica particles,1.5 to 10 µm in diameter,or a L26—Butyl silane chemically bonded to totally porous sil-monolithic silica rod.ica particles,1.5 to 10µm in diameter.L4—Silica gel of controlled surface porosity bonded to a L27—Porous silica particles,30 to 50µm in diameter.sp.infoPeople also askWhat is a chromatographic column?What is a chromatographic column?The Chromatographic Columns online database is a compilation of the chromatographic columns used to validate the chromatographic procedures in USP–NF,Pharmacopeial Forum,Revision Bulletins,and Interim Revision Announcements.Chromatographic Columns USP
Read Moreresults for this questionWhat is an USP column?What is an USP column?The USP Approach for Selecting Columns of Equivalent Selectivity.The USP Database was developed by the USP Working Group on Column Equivalency using the NIST SRM 870.All data being displayed was generated by the column manufacturers after evaluation of the chromatographic phase.The USP Approach for Selecting Columns of Equivalent Selectivity USPsp.info results for this questionWhat are the different types of chromatography?What are the different types of chromatography?The types of chromatography useful in qualitative and quantitative analysis that are employed in the USP procedures are column,gas,paper,thin-layer,(including high-performance thin-layer chromatography),and pressurized liquid chromatography (commonly called high-pressure or high-performance liquid chromatography).General Chapters <621> CHROMATOGRAPHY
Read Moreresults for this questionWhat is USP approach for selecting columns of equivalent selectivity?What is USP approach for selecting columns of equivalent selectivity?The USP Approach for Selecting Columns of Equivalent Selectivity The USP Database was developed by the USP Working Group on Column Equivalency using the NIST SRM 870 .All data being displayed was generated by the column manufacturers after evaluation of the chromatographic phase.The USP Approach for Selecting Columns of Equivalent Selectivity USPsp.info results for this questionFeedbackGeneral Chapters <621> CHROMATOGRAPHY
The types of chromatography useful in qualitative and quantitative analysis that are employed in the USP procedures are column,gas,paper,thin-layer,(including high-performance thin-layer chromatography),and pressurized liquid chromatography (commonly called high-pressure or high-performance liquid chromatography).Paper and thin-layer chromatography are ordinarily more useful for purposes of
Read MoreUSP Chapter 621 changes - Crawford Scientific
No change of the physicochemical characteristics of the stationary phase permitted,i.e.,chromatographic support,surface modification,and extent of chemical modification must be the same; a change from totally porous particle (TPP) columns to superficially porous particle (SPP) columns is allowed provided these requirements are met.sp.infoUSP L Column Listing - Waters CorporationaNaLYTICaL ChROMaTOGRaPhY waters Analytical Chromatography 113 USP “L” Column Listing L1 Octadecyl silane (ODS or C 18) chemically bonded to porous silica or ceramic particles - 1.5 to 10 µm in diameter.See new subclassification table on previous page.Brand Particle Size Type Page AccQ•Tag Ultra 1.7 Spherical 240 ACQUITY UPLC CSH C
Read MoreUSP L## packings for HPLC columns
USP L## packings for HPLC columns L PACKING BRAND NAME MANUFACTURER/ VENDOR L1 Octadecyl silane chemically bonded to porous or non-porous silica or ceramic micro-particles,1.5 to 10 µm in diameter,or a monolithic rod Acclaim 120 C18 Acclaim Polar Advantage II ACE C18-300 ACE AQ ACE C18 ACE C18-AR ACE C18-PFP ACE Excel AQ ACE Excel C18sp.infoGC Column Cross-Reference Columns by Phase / GC28 rows·Columns by phase cross-reference chart for GC columns. Cookies allow for a variety
Read MoreRESTEKPHASE DESCRIPTIONUSP NOMENCLATUREAGILENTRtx-1dimethyl polysiloxaneG1,G2,G38HP-1,DB-1,CP-Sil 5 CBRxi-1HTdimethyl polysiloxane-DB-1HTRxi-1msdimethyl polysiloxane-HP-1ms,HP-1ms UI,DB-1ms,DRtx-5 Rtx-5MSdiphenyl dimethyl polyG27,G36HP-5,DB-5,CP-Sil 8 CB 28 rows on restekAllowable Adjustments to United States Pharmacopeia
8.Column temperature ± 10° C 9.Wavelength of UV-visible detector No deviations permitted 10.Injection volume Can be reduced as long as precision and detection limits are achieved (no increase is permitted) Allowable Adjustments to United States Pharmacopeia (USP) Methods As of August 22,2012 Source United States Pharmacopeia General sp.infoRelated searches for chromatographic columns uspusp column classificationusp column typeusp column listusp column comparisonusp hplc column equivalencyusp general chapter chromatographyusp chromatographyusp hplc12345NextUSP Chromatographic Columns
Read MoreGeneral Chapters <621> CHROMATOGRAPHY - COLUMN CHROMATOGRAPHY
Apparatus— The apparatus required for column chromatographic procedures is simple,consisting only of the chromatographic tube itself and a tamping rod,which may be needed to pack a pledget of glass wool or cotton,if needed,in the base of the tube and compress the adsorbent or slurry uniformly within the tube.In some cases a porous glass disk is sealed at the base of the tube in order to sp.infoL8 - HPLC Columns,by USP Code Sigma-AldrichUSP L8 HPLC Columns An essentially monomolecular layer of aminopropylsilane chemically bonded to totally porous silica gel support,3 to 10 μm in diameter.Note We have only included the most popular dimensions of our preferred brands in the selection below.
Read MoreUSP Chapter 621 changes - Crawford Scientific
No change of the physicochemical characteristics of the stationary phase permitted,i.e.,chromatographic support,surface modification,and extent of chemical modification must be the same; a change from totally porous particle (TPP) columns to superficially porous particle (SPP) columns is allowed provided these requirements are met.sp.infoHPLC and UHPLC Columns Thermo Fisher Scientific - USWith over 40 years as a leader in LC column technology,you can rely on the quality of Thermo Scientific™ HPLC and UHPLC columns.Our extensive family of products offers a variety of particle sizes and column designs to meet all separation needs,including improved resolution,enhanced sensitivity,faster analysis and consistent performance.
Read MoreUSP LISTING OF HPLC COLUMNS
USP LISTING OF HPLC COLUMNS L PackingBrand Name Brand Name L37 L38 L39 L40 L41 L43 L44 L51 L48 L49 L52 L53 L54 L55 L56 L57 L58 L59 L60 L61 Packing having the capacity to separate proteins by molecular size over a range of 4,000 to 400,000 daltons.It is spherical,silica-based,and processed to provide pH stability Strong cation-exhange resin sp.infoAllowable Adjustments to United States Pharmacopeia8.Column temperature ± 10° C 9.Wavelength of UV-visible detector No deviations permitted 10.Injection volume Can be reduced as long as precision and detection limits are achieved (no increase is permitted) Allowable Adjustments to United States Pharmacopeia (USP) Methods As of August 22,2012 Source United States Pharmacopeia General
Read MoreAgilent JW GC Columns Agilent
Agilent JW GC columns have the widest range of standard,GC/MS,and Ultra Inert stationary phases to deliver consistent column inertness and exceptionally low column bleed with high upper temperature limits,ensuring accurate peak identification and quantification for your gas chromatography analysis.sp.infoGood Chromatographic Practices - SlideShareNov 05,2019·Good Chromatographic Practices 1.Dr.A.Amsavel,M.Sc.,B.Ed.,Ph.D 2.Content Introduction Solvents Reagent Quality Mobile phase preparation usage Buffer,Filtration,Degassing Storage usage Preparation for analysis Sample preparation System suitability Adjustment allowed as per USP Column management Washing and change of mobile phase Analysis and integration
Read MoreU.S.Pharmacopeia
The United States Pharmacopeia (USP) was created nearly 200 years ago,dedicated to instilling trust where it matters most in the medicines,supplements and foods people rely on for their health.The quality standards we develop help manufacturers deliver on their promises of safe products,while building confidence among healthcare sp.infoL1 - HPLC Columns,by USP Code Sigma-AldrichUSP L1 HPLC Columns Octadecyl silane chemically bonded to porous silica or ceramic micro-particles,1.5 to 10 μm in diameter,or a monolithic rod.Note We have only included the most popular dimensions of our preferred brands in the selection below.
Read MoreHPLC Columns Chromatography Columns HPLC Hamilton
Hamilton Company has been developing and manufacturing pressure-stable,polymeric,high-performance liquid chromatography (HPLC) columns for more than 35 years.Hamilton offers everything from HPLC columns to syringes to GC septa and more.Click to learn more.sp.infoFAQs Chromatography USPThe most updated information on the brand name of the column used to validate any chromatographic procedure in USP—NF,together with possible alternatives,where applicable are available at the following uspchromcolumns.
Read MoreFAQs Reagents USP
The most updated information about chromatographic columns in USP can be found on the USP Chromatographic Columns Web site (sign-in required).In some cases you can also find information about alternative columns.sp.infoRelated searches for chromatographic columns uspusp column classificationusp column typeusp column listusp column comparisonusp hplc column equivalencyusp general chapter chromatographyusp chromatographyusp hplcSome results are removed in response to a notice of local law requirement.For more information,please see here.Previous123456NextGeneral Chapters <621> CHROMATOGRAPHY - COLUMN CHROMATOGRAPHY
Read MoreL10 - HPLC Columns,by USP Code Sigma-Aldrich
USP L10 HPLC Columns Nitrile groups chemically bonded to porous silica particles,3 to 10 μm in diameter.Note We have only included the most popular dimensions of our preferred brands insp.infoL7 - HPLC Columns,by USP Code Sigma-AldrichUSP L7 HPLC Columns Octylsilane chemically bonded to totally porous silica particles,1.5 to 10 μm in diameter,or a monolithic silica rod.Note We have only included the most popular dimensions of our preferred brands in the selection below.
Read MoreSecond Supplement to USP 35–NF 30 Reagents
5792Chromatographic Columns / Reagents Second Supplement to USP 35–NF 30 L3—Porous silica particles,1.5 to 10 µm in diameter,or a L24—A semi-rigid hydrophilic gel consisting of vinyl monolithic silica rod.polymers with numerous hydroxyl groups on the matrix sur-sp.infoL67 - HPLC Columns,by USP Code Sigma-AldrichUSP L67 HPLC Columns Porous vinyl alcohol copolymer with a C18 alkyl group attached to the hydroxyl group of the polymer,2 to 10 μm in diameter.Note We have only included the most popular dimensions of our preferred brands in the selection below.
Read MoreHPLC Column Classification
most of the USP chromatographic procedures,but in many cases these tests are not conclusive to ensure column inter-changeability.Evidently the current classification nomen-clature does not provide sufficient information to fill the needs of modern liquid chromatography.THE USP APPROACH In an attempt to facilitate the selection of possible sp.infoUSP <621> Modernization USP-NF 37 - WatersWhy is Chromatography <621> Important? Question From CURRENT USP -NF Online FAQs1 – Q.How much can I modify a chromatographic procedure and still be in compliance? Can column length,internal diameter,mobile phase composition be modified? – A.Chromatography <621> contains a list of allowed adjustments to chromatographic systems.
Read MoreIon Chromatography Columns Thermo Fisher Scientific -
Dionex IonPac columns are IonPac polymeric columns for use with hydroxide,carbonate,and methanesulfonic acid eluents.Eluents can be delivered by Reagent-Free™ Ion Chromatography (RFIC™) systems using eluent generation cartridges.sp.infoGood Chromatographic Practices - SlideShareNov 05,2019·Good Chromatographic Practices 1.Dr.A.Amsavel,M.Sc.,B.Ed.,Ph.D 2.Content Introduction Solvents Reagent Quality Mobile phase preparation usage Buffer,Filtration,Degassing Storage usage Preparation for analysis Sample preparation System suitability Adjustment allowed as per USP Column management Washing and change of mobile phase Analysis and integration
Read MoreUSP L Column Listing - HPLC Columns Bulk Media SMT
It is important to note that,in many cases,USP column specifications are so broad that several (or many) column types actually meet the basic specications.For example,L1 specification calls for a column consisting of silica packing material,5 or 10µm in diameter,bonded with octadecyl (C18) silane.sp.infoGeneral Chapters <621> CHROMATOGRAPHY -The types of chromatography useful in qualitative and quantitative analysis that are employed in the USP procedures are column,gas,paper,thin-layer,(including high-performance thin-layer chromatography),and pressurized liquid chromatography (commonly called high-pressure or high-performance liquid chromatography).Paper and thin-layer chromatography are ordinarily more
Read MoreUnited States Pharmacopeia (USP) GC Phases Products
United States Pharmacopeia (USP) GC Phases.In the United States Pharmacopoeia,the stationary phases of GC and HPLC (column liquid phase,carrier,etc.) are indicated with a code number.Representative code numbers and corresponding capillary columns are summarized in the table below.sp.infoChromatography Columns VWRThe right chromatography control system allows to automate the delivery of cleaning,sanitizing and conditioning buffers to the packed column,and can enable to cycle the chromatography column several times during the batch,requiring smaller columns and subsequent lower capital investment.
Read MoreFAQs Reagents USP
The most updated information about chromatographic columns in USP can be found on the USP Chromatographic Columns Web site (sign-in required).In some cases you can also find information about alternative columns.sp.infoRelated searches for chromatographic columns uspusp column classificationusp column typeusp column listusp column comparisonusp hplc column equivalencyusp general chapter chromatographyusp chromatographyusp hplc
Read More
- Alloy Steel Plate
- Automobile Structure Steel Plate
- Boiler and Pressure vessel steel plate
- Carbon and Low alloy High strength Steel Plate
- Clad Steel Plate
- Cold Rolled Steel Coil
- Gas Cylinder Steel coil
- Pipeline steel plate
- Steel Pipe